Easy Touch

High voltage tester with built-in Windows PC.

Description

The Cirris Easy Touch is a high voltage benchtop tester that can easily be moved between test devices. A full color touch-screen display allows you to test with the power of a PC without the hassle of a separate computer, keyboard, and mouse.

Info

Standalone Benchtop Tester

  • Up to 1024 points with add-on boxes (128 pts/box)
  • Interchangeable adapters
  • IPC-WHMA A-620 Compliant
    • Meets requirements for classes 1, 2, and 3.
  • 1500VDC
  • 1000VAC

Built-in Windows 7 PC

  • 10.4” full color touch-screen display
  • Runs Cirris easy-wire software
    • Access to easy-wire user help system
  • Hard-drive
  • VGA
  • USB
  • Ethernet
  • Audio ports

Reliable and Capable

  • Tests for
    • Opens
    • Shorts
    • Miswires
  • Verifies solder and crimp terminations
  • Measures resistance
  • Insulation resistance and DWV testing (1500VDC-1000VAC optional)
  • Tests Components
    • Resistors
    • Diodes
    • Capacitors
    • LEDs
    • Switches
    • Twisted pairs
  • 4-Wire “Kelvin” Testing capable
  • Optional custom scripting available

Specs

Test Points

128 points; expandable to 1,024 points in 128-point increments

Low Voltage Test

2 Wire

  • Voltage: 4 V max
  • Current: 3 μA to 6 mA
  • Resistance: 0.1 Ω to 100 kΩ ± 1% ± 0.1 Ω, 100 kΩ to 5 MΩ ± 10%

4 Wire

  • Voltage: 4 V max
  • Current: 1 mA to 1 A
  • Resistance: 0.001 Ω to 10 Ω ± 2% ± 0.001 Ω

Component Tests

  • Diodes: Silicon, LEDs, zeners with breakdown > 4 V
  • Resistors: 0.1 Ω to 100 kΩ ± 1% ± 0.1 Ω, 100 kΩ to 5 MΩ ± 10%
  • Capacitors: 5 nF to 100 μF ±10% ± 0.02 nF
  • Twisted Pairs: Verify proper pairing in twisted pair cables

High Voltage Test

Insulation Resistance Test

  • Voltage: 50 to 1500 VDC ± 5% ± 5 V (2000 VDC optional)
  • Resistance: 5 MΩ to 1000 MΩ ± 10%

Dielectric Withstand Test

  • Voltage: 50 to 1500 VDC ± 5% ± 5 V (2000 VDC optional, 50 to 1000 VAC optional)
  • Current Limit: 0.1 mA to 1.5 mA
  • Max Capacitance Per Net: 150 nF @ 300 VDC, 90 nF @ 500 VDC, 45 nF @ 1000 VDC, 30 nF @ 1500 VDC, 9.5 nF @ 1000 VAC
  • HV Energy Limit: 35 mJ
  • HV Charge Limit: 45μC

Max Points Per Net

512

Digital Input/Output

4 Inputs / 6 Outputs, 24 V Open collector, +10 V and +5 V each current limited to 100 mA

Test Point Interface

Cirris Adapter System

User Interface

  • Built-in Windows PC with Windows 7® Embedded
  • Display: 10.4” Full-Color Graphical Touch Screen display

Power

115 / 230 V 50/60 Hz

Size

  • Main unit: 17.5”w x 9”h x 5”d (44.5 cm x 23 cm x 13 cm)
  • Add-on box: 6.5”w x 9”h x 5”d (16.5 cm x 23 cm x 13 cm)

Weight

  • Main unit: 18 lbs (8.2 kg)
  • Add-on box: 6.5 lbs (2.9kg)

Options

Easy Touch Voltage and Point Options

  • 1500VDC 128 points (C151-ET) – Standard option
  • Low Voltage 128 points (C15L-ET)
  • 1500VDC 64 points (C1ET-64)
  • 2000VDC 64 points (C2ET-64)
  • 2000VDC 128 points (C200-ET)

S1KV-AC AC option for Easy Touch (1000VAC)

  • Adds an AC voltage source to the high voltage (hipot)
  • Perform hipot tests that are in AC instead of DC
  • Call 1-800-441-9910 for details on how to upgrade. We will need your serial number and unit model when you call.

SIO-EW Digital I/O option for Easy Touch

  • Remotely “Start Test” with an external switch, start button, input from a PLC, etc.
  • Use Palm buttons, light curtains etc. as a hipot safety switch

SPC-MV SPC Measured Values option for Easy Touch

  • Offers greater reassurance regarding the validity of your tests and quality of the testing being performed
  • Help you notice engineering trend patterns in the testing process, such as when fixtures and pins are wearing out due to an increasing level of inconsistency and higher resistance
  • Allow the tester to collect and print or electronically store the measured values of your low voltage tests, high voltage tests, and readings of components to the reporting system of the tester
  • Provides one line per measurement of your assembly as opposed to the default passed/failed results
  • Enabled via a purchased software code either at the time of order or even years later in the field. You may be asked to install the latest software version to use the up-to-date features of this product.

SCPT-ET Scripting option for Easy Touch

  • Create complex tests that are easy for line workers to use
  • Make highly customized reports or cable tags
  • Control external devices such as lamps, hold-down clamps, markers, etc.
  • Test devices such as switches, gas fuses, zener diodes, bi-color diodes, etc.
  • Verify color and lighting of LEDs
  • Display prompt messages
  • Hipot different nets at different voltages

LAN-ET Server Software for easy-wire (up to 5 testers)

  • Provides centralized management of Security Settings, Test Programs, and Test Reports data
  • Manage your tester needs from any client connected to the Cirris Server Software
  • Server and Clients must be running the same version

SLD-LK Slide-Lock Scanner Upgrade (New 1500VDC Easy Touch testers ship with this upgrade)

  • Allows operators to lock adapters in place without using a removable cover plate
  • Hold adapters firmly in place to reduce connector wear

Performance Verification

  • The Easy Touch Performance Check Kit allows you to verify the calibration and proper operation of the Easy Touch tester.
  • For information on tester calibration, click here.
  • For documentation on Performance Check Kits for the Easy Touch click on the Documentation tab on this page.

Software

Easy Touch Version Lookup

On the main menu screen of easy-wire, the verson number is located on the mid-right side of the window.